Top.Mail.Ru

Auditory Electrophysiology Lab

Neuro-Audio


  • all-in-one solution for auditory EP and OAE acquisition
  • automatic multi-ASSR test
  • VEMP with biofeedback
  • diagnosis of Meniere's disease
Auditory Electrophysiology Lab

Description

ANVISA BATTERI BLUETOOTH CE CFDA EAC Включено в единый реестр ПО FDA ISO TGA USB WI-FI

All-in-One Solution for Auditory EP and OAE Acquisition

A full range of objective and subjective techniques for the diagnostics of hearing and balance is in the one compact-sized device now! Using this device, you can perform ABR, ASSR, multi-ASSR, MLR, LLR/CAEP, TEOAE, DPOAE, SOAE, ECochG, VEMP, P300, MMN, pure tone audiometry techniques easily.

Automatic Multi-ASSR Test

Multi-ASSR test implemented in the Neuro-Audio system reduces the test duration due to the automatic intensity switching for hearing threshold search, stimulation of both ears simultaneously by 8 frequencies (4 in each ear, from 500 Hz to 4000 Hz), and frequency-specific Chirp stimulus which takes the cochlear anatomy into account to increase the response amplitude. The test result is represented as the estimated pure tone audiogram used further for hearing aid fitting.

VEMP with Biofeedback

Dizziness is one of the main reasons for visiting a doctor (up to 30–40% of all visits according to Neuhauser 2005, Geser & Straumann 2012). Neuro-Audio can also be used successfully in the diagnosis of vestibular disorders.

The system ensures full state-of-the-art support of VEMP tests, including VEMP with biofeedback, VEMP amplitude scaling by mean EMG activity level, and also a unique function of EMG histogram with post-hoc analysis (important for children). Supported techniques: cervical and ocular VEMP tests (cVEMP and oVEMP).

Diagnosis of Meniere's Disease

Electrocochleography (ECochG) is used to diagnose Meniere's disease and endolymphatic hydrops. In addition to the traditional SP/AP amplitude ratio calculation (which has a low sensitivity to this pathology), the Neuro-Audio software calculates SP/AP area ratio. That’s why the system is one among the few devices in the world that can significantly increase the sensitivity of the technique in the diagnosis of Meniere's disease.

The support of HL7 standard allows integrating all diagnostic Neurosoft systems into the information system of a healthcare facility.

Delivery Set

The delivery set can differ from country to country. Request the actual delivery set for your country from your local representative.

Neuro-Audio1 pcs.
Neuro-Audio electronic unit1 pcs.
H-1S assembled holder1 pcs.
Holder mount1 pcs.
OAE-02-2 probe1 pcs.
OAE probe tip3 pcs.
Set of eartips (universal)1 pcs.
Superfloss Regular dental floss1 pcs.
Probe tip extractor1 pcs.
Test cavity1 pcs.
Cup electrode with cable (5 pcs., 1 m)1 pcs.
Y-adapter1 pcs.
Adapter for 2-channel EP recording1 pcs.
Disposable ECG electrode F9049100 pcs.
Cable for disposable electrode with alligator clip and touch-proof connector (white, 1 m)1 pcs.
Cable for disposable electrode with alligator clip and touch-proof connector (red, 1 m)1 pcs.
Cable for disposable electrode with alligator clip and touch-proof connector (black, 1 m)1 pcs.
Cable for disposable electrode with alligator clip and touch-proof connector (blue, 1 m)1 pcs.
TDH-39 auditory stimulator, shielded1 pcs.
Ten20 сonductive paste1 pcs.
Uniscrab abrasive gel1 pcs.
Transpore medical tape1 pcs.
Technical Manual «Neuro-Audio»1 pcs.
Warranty certificate1 pcs.
User manual «Neuro-Audio.NET»1 pcs.
Guidelines "OAE Probes OAE-02, OAE-03, OAE-04 and aScreen Probe"1 pcs.
Calibration Guidelines "Neuro-Audio"1 pcs.
Guidelines "EABR Test"1 pcs.
Guidelines "VEMP: Vestibular Evoked Myogenic Potential"1 pcs.
Guidelines "How to get quality ABR and ASSR recordings"1 pcs.
Package set1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/VEMP"1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/OAE"1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/ABR"1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/ASSR"1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/Multi-ASSR"1 pcs.
Equipment for Cognitive EP Study Using P300 Technique1 pcs.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/CEP"1 pcs.
License for the use of software «Neuro-Audio.NET» with additional software module «Neuro-Audio.NET/ECochG»1 pcs.
ER-3С-10 insert audiometric earphones1 pcs.
Ear tip ER3-14A (13 mm)10 pcs.
Ear tip (ER3-14B 10 mm)10 pcs.
1 pcs.
Cable for ECochG electrode1 pcs.
ECochG electrode, adult20 pcs.
ECochG electrode, pediatric20 pcs.
Electrode gel Unimax (250 g)1 pcs.
Bone vibrator1 pcs.
KM-7-2 USB hub with cable1 pcs.
KM-7-2 USB-hub1 pcs.
USB cable (A-B)1 pcs.
SCZ-1 mains supply cable1 pcs.
Technical Manual1 pcs.
Elite System unit1 pcs.
Monitor 21.5"1 pcs.
Printer1 pcs.

accomodation account achievement alphabet arrow-full arrow calendar-2 calendar check close collapse-widget compare contact-us download event-link expand file-link Приказ file geolocation gov holidays-icon home link location logout msg-send msg-success-cheer msg-success neuron new-menu pdf person phone-back phone questions roll-up rotating_circle search shop view-list view-tile write-us fb insta sk tw vk youtube